Cleanliness and micro-contamination analyses are crucial for ensuring quality, minimizing the risk of contamination-related failure and adhering to relevant specifications. To ensure the competence of our testing procedures, we conduct regular correlation tests with the hard disk drive manufacturers.
| Cleanliness Tests on | |
|
|
Technical Specifications
Test parameters include, but are not limited to:
| Ion-Chromatography (IC) | |
| • Anions | - Fluoride, Chloride, Bromide, Nitrate, Nitrite, Phosphate, Sulphate, Oxalate |
| • Cations | - Lithium, Sodium, Calcium, Potassium, Magnesium, Ammonium |
| Fourier Transfer Infra-Red (FTIR) |
| • Qualification and quantification analyses of silicone, amide, phthalate ester (DOP) and hydrocarbon |
| • Analysis of embedded or loose organic debris, surface organic residue, like fiber, stain, polymeric particles (e.g. PET, PC, PP, etc.), oil and lubricant, etc. |
| • Plastic Material Verification |
| Non-Volatile Residues (NVR) |
| • NVR Test (extraction by DI water, IPA, Hexane or Acetone) |
| Scanning Electron Microscope / Energy Dispersive X-Ray (SEM/EDX) |
| • Ghost Test • Mg/Si/O talc • MESA Test • Surface structure inspection for micro defect like crack, embedded particulate, or corrosion product. • APA (Automated Particle Assessment) • HPA (Hard Particle Analysis • Composition Analysis) • Micro-contamination analysis • KPA (Killer Particle Analysis) • Carbon Tape Test • Filler Test, etc. |
| Gas Chromatography - Mass Spectrometry (GC-MS) |
| • Repeated Hydrocarbon • CVR (Condensable Volatile Residue) • TPPO (Triphenyl phosphine oxide) • Organic Residue, Hydrocarbon (C18 to C40), Irgafos & Phthalate elemental particles • Outgassing Test by Dynamic Headspace (DHS) GC/MS or Condensable Analysis to check outgassed volatile organic compounds, etc. |
| Liquid Particle Count (LPC) |
| • Particle size: 0.5-1.0 µm, 1.0 -5.0 µm, 5.0 -10 µm, 10-20 µm, 20-50 µm, 50-100 µm |
| Inductively Coupled Plasma - Optical Emission Spectrometry (ICP-OES) or Inductively Coupled Plasma - Mass Spectrometry (ICP-MS) |
| • Extractable Metals – Zinc, Lithium, Potassium, Calcium, Magnesium, Sodium, Copper, Tin, Titanium, etc. |
| Others |
| • Corrosion / Thermal Cycle Test • Acidity (Delta H) • Turbidity, etc. |